کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2758492 1567560 2006 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Arm and ankle blood pressure during caesarean section
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیهوشی و پزشکی درد
پیش نمایش صفحه اول مقاله
Arm and ankle blood pressure during caesarean section
چکیده انگلیسی

BackgroundWe have previously reported that measurement of non-invasive blood pressure during caesarean section under spinal anaesthesia fails in over 50% of cases. We felt that errors would be less likely if blood pressure could be measured at the ankle as it is immobile during caesarean section. The purpose of our study was to determine whether blood pressure measurement at the ankle was equivalent to the arm.MethodFollowing ethical approval, informed consent was obtained from 30 women scheduled for elective caesarean section. Two non-invasive blood pressure cuffs, one on the upper arm and one on the ankle, were used to measure blood pressures at three timed intervals: before spinal insertion, before surgery and after delivery of the neonate.ResultsUsing the method of Bland and Altman we found that there was only marginal agreement between the two methods. On eight out of 15 occasions where there was a greater than 20% fall in arm systolic blood pressure, this was not detected at the ankle.ConclusionWe cannot recommend the use of the ankle to measure blood pressure during caesarean section.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Obstetric Anesthesia - Volume 15, Issue 1, January 2006, Pages 24–27