کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2881049 1573997 2007 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Late Disruption of a Freestyle Stentless Bioprosthesis Used for Repair of Sinus of Valsalva Aneurysm of Noncoronary Cusp
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Late Disruption of a Freestyle Stentless Bioprosthesis Used for Repair of Sinus of Valsalva Aneurysm of Noncoronary Cusp
چکیده انگلیسی
We present a case of disruption of the porcine aortic wall of the 27-mm Freestyle stentless bioprosthesis 5 years after the subcoronary implantation to exclude the sinus of Valsalva aneurysm of the noncoronary cusp. At the urgent reoperation, the inflow suture line was found to be intact, and therefore a new stented valve was sutured with the inflow Dacron cuff after removal of ruptured valve. The subcoronary implantation technique creates a cavity between the prosthetic and native aortic walls filled with hematoma. The outflow suture line dehiscence caused blood flow into the cavity, porcine aortic wall rupture, and leaflet destruction.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Annals of Thoracic Surgery - Volume 83, Issue 6, June 2007, Pages 2210-2213