کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2886411 1574206 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Outcomes after Arterial Endovascular Procedures Performed in Patients with an Elevated International Normalized Ratio
ترجمه فارسی عنوان
نتایج پس از روشهای انسانیال شریانی انجام شده در بیماران با افزایش نسبت عادی بین المللی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی

BackgroundPatients treated with anticoagulants frequently require urgent vascular procedures and elevated prothrombin time/international normalized ratio (INR) is traditionally thought to increase access site bleeding complications after sheath removal. We aimed to determine the safety of percutaneous arterial procedures on patients with a high INR in the era of modern ultrasound-guided access and closure device use.MethodsPatients undergoing arterial endovascular procedures at a single institution between October 2010 and November 2012 were reviewed (n = 1,333). We retrospectively analyzed all patients with an INR > 1.5. Venous procedures, lysis checks, and cases with no documented INR within 24 hr were excluded. Sixty-five patients with 91 punctures were identified. A comparison group was then generated from the last 91 patients intervened on with INR < 1.6. Demographics, intraoperative data, and postoperative complications were compared.ResultsThe demographics were similar. More Coumadin use and higher INR were found in the study group (71/91 and 0/91, P = 0.001; 2.3 and 1.1 sec, P = 0.001, respectively), but there was more antiplatelet use in the control group (68/91 and 51/91, P = 0.01). Intraoperatively, the sheath sizes, protamine use, closure device use, ultrasound guidance, brachial access, and procedure types were not statistically different. Sheath sizes ranged from 4 to 22F in the study group and 4 to 20F in the control group. Paradoxically, heparin was administered more frequently in the study group (64/91 and 50/91, P = 0.046). Bleeding complications occurred more commonly in the study group (3/91 and 1/91, P = 0.62), but this failed to reach significance and the overall complication rate in both groups was low.ConclusionsEndovascular procedures may be performed safely with a low risk of bleeding complications in patients with an elevated INR. Ultrasound guidance and closure device use may allow these cases to be performed safely, but a larger series may be needed to confirm this.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Annals of Vascular Surgery - Volume 29, Issue 1, January 2015, Pages 22–27
نویسندگان
, , , , ,