کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2905789 1173436 2006 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Angled Forceps Used for Transbronchial Biopsy in Which Standard Forceps Are Difficult To Manipulate : A Comparative Study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Angled Forceps Used for Transbronchial Biopsy in Which Standard Forceps Are Difficult To Manipulate : A Comparative Study
چکیده انگلیسی

Objectives:To evaluate the usefulness of the Sasada transbronchial angled forceps (STAF) in patients with peripheral pulmonary lesions (PPLs), which are difficult to manipulate with standard forceps.Methods:We have invented the STAF, a forceps with an angled tip. One hundred ten patients with PPLs that were difficult to reach with standard forceps were retrospectively evaluated. The patients first underwent bronchoscopy with a standard forceps and then with the STAF. The specimens obtained with standard forceps and those obtained with STAF were separately fixed and analyzed histologically. We compared the histologic diagnosis of the specimens obtained by STAF with that obtained by the specimens obtained with standard forceps. Statistical significance was calculated with the McNemar χ2 statistic.Results:The diagnostic yield of all lesions from the specimens obtained with STAF (86 of 110 lesions; 78.2%) was significantly higher than that of lesions from the specimens obtained with standard forceps (43 of 110 lesions; 39.1%; p < 0.001). Among malignant lesions, the yield obtained with STAF (60 of 72 lesions; 83.3%) was significantly higher than that obtained with standard forceps (32 of 72 lesions; 44.4%; p < 0.001). Among benign lesions, the yield obtained with STAF (26 of 38 lesions; 68.4%) was also significantly higher than that obtained with standard forceps (11 of 38 lesions; 28.9%; p < 0.001). Among the different lesion areas, the right upper lobe plus the left upper division gave the greatest difference in yield (STAF, 46 of 60 lesions; 76.7%; standard forceps, 22 of 60 lesions; 36.7%; p < 0.001). Among the different size ranges, the diagnostic yields obtained with STAF were significantly higher than that obtained with standard forceps except for the size range of ≤ 10 mm. There were two complications, pneumothorax and bronchial bleeding, both of which were controlled easily.Conclusions:The STAF was shown to be useful for obtaining specimens that were sufficient for histologic diagnosis from PPLs that were difficult to manipulate with standard forceps.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chest - Volume 129, Issue 3, March 2006, Pages 725–733
نویسندگان
, , , , , , ,