کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2911751 1575430 2016 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Amplatzer Plug to Occlude the Internal Iliac Artery During Endovascular Aortic Aneurysm Repair: A Large Multicenter Study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Amplatzer Plug to Occlude the Internal Iliac Artery During Endovascular Aortic Aneurysm Repair: A Large Multicenter Study
چکیده انگلیسی

ObjectiveDuring endovascular repair of abdominal aortic aneurysms (EVAR), in the absence of a distal iliac landing zone, the Amplatzer plug is increasingly being used to replace other internal iliac artery (IIA) embolization techniques. This study aimed at assessing the technical success, complication occurrence, and durability of the Amplatzer plug for IIA embolization.MethodFrom January 1, 2007 to December 31, 2013, all consecutive patients who underwent internal iliac embolization with an Amplatzer plug during EVAR were included in the study. There were 169 patients, (160 men, 9 women, mean 75 ± 9 years), treated by unilateral (158 cases, 93%) or bilateral (11 cases, 7%) embolization of the IIA, performed either separately prior to (65 cases, 38.5%) or during EVAR (104 cases, 61.5%). Follow up CT scan and/or US scan were performed 1 month after treatment and yearly thereafter. The inclusions were done retrospectively but the series was continuous and consecutive. Data were collected and analyzed using acquisition REDCap software.ResultsThe technical success rate was 97.6%. Failures were device migration (n = 1), navigation failure (n = 2), and release outside the target zone (n = 1). On average, 1.43 plugs were required to achieve the embolization. The average amount of contrast agent for the embolization procedure was 111 ± 51 mL and the radiation dose was 127,777 ± 89,528 mGy/cm2. The total fluoroscopy time was 854 ± 538 seconds. No re-canalization of the IIA trunk was observed during follow up. Complications were buttock claudication (n = 41, 24.3%), which resolved in 24 cases (58.5%, 24/41) at the first follow up, and intestinal ischemia requiring limited bowel resection in two cases.ConclusionThis multicenter study is the largest published to date. It demonstrates the efficacy and reliability of the Amplatzer plug to embolize the IIA during EVAR, with few side effects.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Vascular and Endovascular Surgery - Volume 51, Issue 5, May 2016, Pages 641–646
نویسندگان
, , , , , , , , , , , , ,