Technical and Patient-related Characteristics Associated with Challenging Retrieval of Inferior Vena Cava Filters
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Technical and Patient-related Characteristics Associated with Challenging Retrieval of Inferior Vena Cava Filters
چکیده انگلیسی

ObjectiveTo identify patient-related and device-specific predictors of challenging and failed inferior vena cava (IVC) filter retrievals.MethodsRetrospective single center review of consecutive retrievable IVC filters placed between 2004 and 2009. Retrieval was defined as challenging when it was unsuccessful owing to reported technical failure or when adjunctive endovascular maneuvers or access sites were recruited. Data regarding patient- and filter-specific information were collected. Logistic regression models were used to identify predictors of the reported outcomes. Statistical significance was set at p < .05.ResultsFour hundred and one patients underwent retrievable IVC filter placement—the majority indicated for prophylaxis (67%). Two hundred and fifty-nine retrievals were attempted and 237 filters were successfully retrieved (overall retrieval rate: 59.1%). Eleven out of 259 (4.2%) attempts were aborted owing to significant thrombus within the filter and 11 (4.2%) were technically unsuccessful. In 142 patients no attempt for filter retrieval was made—the major reason being physician oversight (44.3%). Thirty-eight out of 248 (15.3%) non-aborted filter retrievals were recorded as challenging. Failed retrievals were predicted by prolonged dwell time (96.9 ± 111.9 vs. 29.5 ± 25.1 days, odds ratio [OR] 1.034, 95% confidence interval [CI] 1.016–1.053, p < .001), therapeutic indication (OR 5.197, 95% CI 1.200–22.511, p = .028), and filter wall apposition (OR 11.857, 95% CI 2.069–67.968, p = .006). Challenging retrievals were predicted by dwell time (51.1 ± 69.8 vs. 29.1 ± 24.5 days, OR 1.017, 95% CI 1.005–1.029, p = .007), filter tilt (OR 2.607, 95% CI 1.045–6.508, p = .040) and filter wall apposition (OR 6.149, 95% CI 2.398–15.763, p = <.001).ConclusionsPhysician oversight leads to poor IVC filter retrieval rates. Retrievals can be challenging or fail when the dwell time is >50 days and >90 days, respectively, and when the filter hook apposes the caval wall. Filter tilt increases retrieval difficulty but not failure rates.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Vascular and Endovascular Surgery - Volume 46, Issue 3, September 2013, Pages 353–359
نویسندگان
, , , , , , , , ,