کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2913696 1575482 2012 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation of an Electromagnetic 3D Navigation System to Facilitate Endovascular Tasks: A Feasibility Study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Evaluation of an Electromagnetic 3D Navigation System to Facilitate Endovascular Tasks: A Feasibility Study
چکیده انگلیسی

IntroductionWe describe a novel approach to arterial cannulation using the StealthStation® Guidance System (Medtronic, USA). This uses electromagnetic technology to track the guidewire, displaying a 3D image of the vessel and guidewire.MethodsThe study was performed on a ‘bench top’ simulation model called the Cannulation Suite comprising of a silicone aortic arch model and simulated fluoroscopy. The accuracy of the StealthStation® was assessed. 16 participants of varying experience in performing endovascular procedures (novices: 6 participants, ≤5 procedures performed; intermediate: 5 participants, 6–50 procedures performed; experts: 5 participants, >50 procedures performed) underwent a standardised training session in cannulating the left subclavian artery on the model with the conventional method (i.e. with fluoroscopy) and with the StealthStation®. Each participant was then assessed on cannulating the left subclavian artery using the conventional method and with the StealthStation®. Performance was video-recorded. The subjects then completed a structured questionnaire assessing the StealthStation®.ResultsThe StealthStation® was accurate to less than 1 mm [mean (SD) target registration error 0.56 mm (0.91)]. Every participant was able to complete the cannulation task with a significantly lower use of fluoroscopy with the navigation system compared with the conventional method [median 0 s (IQR 0–2) vs median 14 s (IQR 10–19), respectively; p = <0.001]. There was no significant difference between the StealthStation® and conventional method for: total procedure time [median 17 s (IQR 9–53) vs median 21 s (IQR 11–32), respectively; p = 0.53]; total guidewire hits to the vessel wall [median 0 (IQR 0–1) vs median 0 (IQR 0–1), respectively; p = 0.86]; catheter hits to the vessel wall [median 0.5 (IQR 0–2) vs median 0.5 (IQR 0–1), respectively; p = 0.13]; and cannulation performance on the global rating scale [median score, 39/40 (IQR 28–39) vs 38/40 (IQR 33–40), respectively; p = 0.40]. The intra-class correlation coefficient for agreement between video-assessors for all scores was 0.99. 88% strongly agreed that the StealthStation® can potentially decrease exposure of the patient to contrast and radiation.ConclusionArterial cannulation is feasible with the StealthStation®.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Vascular and Endovascular Surgery - Volume 43, Issue 1, January 2012, Pages 22–29
نویسندگان
, , , , , ,