کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2914748 1575550 2006 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Dynamic Cine-CT Angiography for the Evaluation of the Thoracic Aorta; Insight in Dynamic Changes with Implications for Thoracic Endograft Treatment
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Dynamic Cine-CT Angiography for the Evaluation of the Thoracic Aorta; Insight in Dynamic Changes with Implications for Thoracic Endograft Treatment
چکیده انگلیسی

ObjectiveThoracic aneurysm preoperative imaging is performed using static techniques without consideration of normal aortic dynamics. Improved understanding of the native aortic environment into which thoracic endografts are placed may aid in device selection. It is unclear what comprises normal thoracic aortic pulsatility. We studied these phenomena dynamically using ECG-gated 64-slice CTA.MethodsMaximum diameter and area change per cardiac cycle was measured at surgically relevant anatomic thoracic landmarks in ten patients; 1.0 cm proximal and distal to the subclavian artery, 3.0 cm distal to the subclavian artery, and 3.0 cm proximal to the celiac trunk. Data was acquired using a novel ECG-gated dynamic 64-slice CT scanner during a single breath hold with a standard radiation dose and contrast load. Eight gated data sets, covering the cardiac cycle were reconstructed, perpendicular to the central lumen.ResultsThere is impressive change in both maximum diameter and area in the thoracic aorta during the cardiac cycle. Mean maximum diameter changes of greater than 10% are observed in the typical sealing zones of commercially available endografts corresponding to diameter increases of up to 5 mm. Aortic area increases by over 5% per cardiac cycle.ConclusionsECG-gated dynamic CTA with standard radiation dose is feasible on a 64-slice scanner and provides insight into (patho) physiology of thoracic aortic conformational changes. Clinicians typically oversize thoracic endografts by 10%. With aortic pulsatility resulting in diameter changes of up to 17.8%, the potential exists for endograft undersizing, graft migration, intermittent type I endoleak, and poor patient outcome. Furthermore, aortic pulsatility is not evenly distributed, and non-circular stentgraft designs should be considered in the future since aortic distension in the aneurysm neck is not evenly distributed.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Vascular and Endovascular Surgery - Volume 32, Issue 5, November 2006, Pages 532–536
نویسندگان
, , , , , , , ,