کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2921828 1175807 2016 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Brain natriuretic peptide and the risk of ventricular tachyarrhythmias in mildly symptomatic heart failure patients enrolled in MADIT-CRT
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Brain natriuretic peptide and the risk of ventricular tachyarrhythmias in mildly symptomatic heart failure patients enrolled in MADIT-CRT
چکیده انگلیسی

BackgroundThere are limited data about the correlation between brain natriuretic peptide (BNP) levels and arrhythmic risk assessment in patients who receive device therapy for the treatment of heart failure (HF) or for the prevention of sudden cardiac death.ObjectivesWe aimed to investigate the association between BNP levels and the risk of ventricular tachyarrhythmias among mildly symptomatic HF patients who receive an intracardiac defibrillator (ICD) with or without cardiac resynchronization therapy (respectively, CRT-D or CRT).MethodsThe study population involved 1197 patients enrolled in MADIT-CRT. Plasma BNP was measured in a core laboratory at baseline and after 1-year follow-up. Ventricular tachycardia/fibrillation (VT/VF) events were identified from ICD/CRT-D interrogations.ResultsMultivariate Cox hazards regression modeling showed that elevated baseline (> median = 72 ng/L) and 1-year BNP were associated with a significant increase in the risk of VT/VF (HR = 1.36, P = .026; and HR = 1.79, P < .001, respectively); and VT/VF or death (HR = 1.37, P = .008; and HR = 1.84, P < .0001, respectively) during follow-up. At 1 year post device implantation, BNP levels were significantly lower among study patients treated with CRT-D as compared with those who received ICD only (P = .014). CRT-D patients who had greater than median reductions in BNP levels (greater than one-third reduction of initial value) experienced a significantly lower risk of subsequent VT/VF (HR = 0.61, P = .021) and VT/VF or death (HR = 0.45, P < .0001) as compared to patients without such reductions.ConclusionsIn MADIT-CRT, elevated baseline and follow-up BNP levels were independent predictors of increased risk for subsequent ventricular tachyarrhythmias, whereas BNP reductions following CRT-D implantation identified patients with a lower incidence of VT/VF during follow-up.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Heart Rhythm - Volume 13, Issue 4, April 2016, Pages 852–859
نویسندگان
, , , , , ,