کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2923179 1175865 2010 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Dual excitation wavelength epifluorescence imaging of transmural electrophysiological properties in intact hearts
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Dual excitation wavelength epifluorescence imaging of transmural electrophysiological properties in intact hearts
چکیده انگلیسی

BackgroundEpifluorescence imaging using voltage-sensitive dyes has provided unique insights into cardiac electrical activity and arrhythmias. However, conventional dyes use blue-green excitation light, which has limited depth penetration.ObjectiveThe aim of this study was to demonstrate that combining a short and a long excitation wavelength using near-infrared (NIR) dyes allows for epifluorescence imaging of transmural electrophysiological properties in intact hearts.MethodsEpifluorescence imaging was performed in rat hearts (N = 11) using DI-4-ANEPPS and the NIR dye DI-4-ANBDQBS. Activation and action potential duration (APD) patterns were investigated at 2 excitation wavelengths (530 and 660 nm) after epicardial stimulation at various cycle lengths (160 to 70 ms).ResultsOptical action potential upstrokes acquired with 660-nm excitation of DI-4-ANBDQBS were significantly longer than upstrokes obtained with 530-nm excitation of DI-4-ANEPPS (P < .001). Comparison of activation maps showed counterclockwise rotation of isochrones consistent with a transmural rotation of myofibers. Pronounced APD modulation by the activation sequence was observed at both excitation wavelengths. Significantly prolonged APDs (P = .016) and steeper APD restitution curves were found with DI-4-ANBDQBS (660-nm excitation) when compared with DI-4-ANEPPS (530-nm excitation). Dual excitation wavelength experiments using solely DI-4-ANBDQBS yielded similar results. Monophasic action potential recordings showed prolonged APD and steeper APD restitution curves in the endocardium, indicating that 660-nm excitation provides a significant endocardial contribution to the signal. Three-dimensional computer simulations confirmed our findings.ConclusionDual excitation wavelength epifluorescence allows detecting transmural heterogeneity in intact hearts. It therefore has the potential to become an important tool in experimental cardiac electrophysiology.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Heart Rhythm - Volume 7, Issue 12, December 2010, Pages 1843–1849
نویسندگان
, , , , , ,