کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2924390 1175904 2008 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Spatial resolution of pace mapping of idiopathic ventricular tachycardia/ectopy originating in the right ventricular outflow tract
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Spatial resolution of pace mapping of idiopathic ventricular tachycardia/ectopy originating in the right ventricular outflow tract
چکیده انگلیسی

BackgroundPace mapping has been used to identify the site of origin of focal ventricular arrhythmias. The spatial resolution of pace mapping has not been adequately quantified using currently available three-dimensional mapping systems.ObjectiveThe purpose of this study was to determine the spatial resolution of pace mapping in patients with idiopathic ventricular tachycardia or premature ventricular contractions originating in the right ventricular outflow tract.MethodsIn 16 patients with idiopathic ventricular tachycardia/ectopy from the right ventricular outflow tract, comparisons and classifications of pace maps were performed by two observers (good pace map: match >10/12 leads; inadequate pace map: match ≤10/12 leads) and a customized MATLAB 6.0 program (assessing correlation coefficient and normalized root mean square of the difference (nRMSd) between test and template signals). With an electroanatomic mapping system, the correlation coefficient of each pace map was correlated with the distance between the pacing site and the effective ablation site. The endocardial area within the 10-ms activation isochrone was measured.ResultsThe ablation procedure was effective in all patients. Sites with good pace maps had a higher correlation coefficient and lower nRMSd than sites with inadequate pace maps (correlation coefficient: 0.96 ± 0.03 vs 0.76 ± 0.18, P <.0001; nRMSd: 0.41 ± 0.16 vs 0.89 ± 0.39, P <.0001). Using receiver operating characteristic curves, appropriate cutoff values were >0.94 for correlation coefficient (sensitivity 81%, specificity 89%) and ≤0.54 for nRMSd (sensitivity 76%, specificity 80%). Good pace maps were located a mean of 7.3 ± 5.0 mm from the effective ablation site and had a mean activation time of −24 ± 7 ms. However, in 3 (18%) of 16 patients, the best pace map was inadequate at the effective ablation site, with an endocardial activation time at these sites of −25 ± 12 ms. Pace maps with correlation coefficient ≥0.94 were confined to an area of 1.8 ± 0.6 cm2. The 10-ms isochrone measured 1.2 ± 0.7 cm2.ConclusionThe spatial resolution of a good pace map for targeting ventricular tachycardia/ectopy is 1.8 cm2 in the right ventricular outflow tract and therefore is inferior to the spatial resolution of activation mapping as assessed by isochronal activation. In approximately 20% of patients, pace mapping is unreliable in identifying the site of origin, possibly due a deeper site of origin and preferential conduction via fibers connecting the focus to the endocardial surface.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Heart Rhythm - Volume 5, Issue 3, March 2008, Pages 339–344
نویسندگان
, , , , , , , , , , ,