BackgroundIf contrast material is injected into the cubital vein, artifacts due to high concentration of the contrast material in the vein lead to deterioration of the opacification of the thoracic aorta and the major branches. We describe a new protocol employing a combination of triple channel contrast material injection and a mixture of saline with acquisition in the cephalic direction utilizing capability of 16-slice multislice CT.Materials and methodsOf 35 subjects who underwent thoracic CT, 18 were injected with 70 ml contrast each prior to scanning with acquisition in the cephalic direction during the injection of 30 ml contrast diluted 50/50 with saline, followed by the injection of 20 ml of saline (new protocol). Seventeen subjects were injected each with 100 ml contrast at 3 ml/s, with scanning in the caudal direction (ordinary protocol).ResultsIn the new protocol, the major branches of the aorta and the left ventricle were more opacified, but the veins were less opacified compared with the ordinary protocol, resulting in clear delineation of the thoracic aorta and the major branches without artifacts.ConclusionsA new acquisition protocol is described in which the thoracic aorta and the major branches can be evaluated without artifact due to high CT values in the veins. Faster, more informative CT scans can be performed using diluted contrast.