BackgroundDevice closure of an atrial septal defect (ASD) results in symptom-reduction, right heart remodelling and lower pulmonary artery pressures. However it is unclear if there is a chronological limit to these benefits and whether device closure is safe in elderly subjects. The aim of this study was, therefore, to assess the safety and efficacy of device closure in patients > 60 years.MethodsRetrospective study of Amplatzer Septal Occluder™ device closures from a single institution (May 1999–August 2002).ResultsFifty subjects aged > 60 years (range 60–85 years) had ASD device closure (27% of the total cohort). Defect size and shunt size were similar for both younger and older groups (2.2 : 1 in both groups, p = 0.9) as were procedural duration, fluoroscopy time and device size deployed. Baseline right ventricular (RV) systolic pressure ((younger vs. older) 39 vs. 49 mmHg, p < 0.001) and right ventricular size (45 vs. 51 mm, p < 0.001) were greater in the older group. Following closure RV systolic pressure (49 vs. 45 mmHg, p < 0.01) and RV size (51 vs. 44 mm, p = 0.01) decreased in the older group.ConclusionDevice closure of an ASD can be performed safely in older patients. The right heart shows signs of remodelling even in elderly subjects.
Journal: International Journal of Cardiology - Volume 107, Issue 2, 15 February 2006, Pages 207–210