کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
2975329 | 1179352 | 2013 | 7 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Pose de chambre implantable par abord percutané échoguidé : à propos d'une série de 102 patients
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت
پزشکی و دندانپزشکی
کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
![عکس صفحه اول مقاله: Pose de chambre implantable par abord percutané échoguidé : à propos d'une série de 102 patients Pose de chambre implantable par abord percutané échoguidé : à propos d'une série de 102 patients](/preview/png/2975329.png)
چکیده انگلیسی
Techniques of insertion of implantable venous devices have been widely described. The use of ultrasound guidance is part of the good practice recommendations of the SOR 2008Â but there are few data in the literature and recommendations are based only on expert agreement. To this end we conducted a prospective, single-center study from January 2008Â to August 2009Â on percutaneous ultrasound-guided insertion of implantable devices. In addition to age, sex, the therapeutic indication and the site of implantation, we identified the operative time and number of venipunctures performed for each procedure. We then identified the infectious complications at three months and thromboembolic complications at 1Â year and a half. Our study examined 102Â consecutive patients. The mean age was 61.8Â years (28-90); 71% of patients were men. For 101Â patients, the internal jugular vein was punctured, the subclavian vein in one patient. In 86% of cases, the implantable venous device was inserted into the right vein. The average length of procedure was 30Â minutes (18-60) for a single-vein puncture. Among the 102Â patients, the overall morbidity was 7.8% with four infections (3.9%) and four thromboses (3.9%). There were no immediate perioperative complications (arterial puncture, hematoma, pneumothorax). In conclusion, percutaneous ultrasound-guided insertion of implantable venous devices in the internal jugular vein is a safe, minimally invasive technique which complies with the 2008Â SOR recommendations by preventing the risk of venous thrombosis and avoiding repeated venous puncture. Less invasive than the open surgical approach, ultrasound-guided insertion is safer than puncture based solely on anatomical landmarks. In summary, this is a reliable, simple and easily reproducible technique which limits iatrogenic risks and improves patient comfort.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal des Maladies Vasculaires - Volume 38, Issue 1, February 2013, Pages 6-12
Journal: Journal des Maladies Vasculaires - Volume 38, Issue 1, February 2013, Pages 6-12
نویسندگان
V. Nguyen, J. Jarry, P. Farthouat, N. Bourilhon, F. Milou, P. Michel,