کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2980436 1578606 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Clinical performance of a sutureless aortic bioprosthesis: Five-year results of the 3f Enable long-term follow-up study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Clinical performance of a sutureless aortic bioprosthesis: Five-year results of the 3f Enable long-term follow-up study
چکیده انگلیسی

ObjectiveSutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn).MethodsBetween March 2007 and December 2009, 141 patients (54 male; mean age, 76.1 ± 5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory.ResultsThe mean systolic gradient was 10.4 ± 4.4 mm Hg at discharge and 7.7 ± 4.1 mm Hg at 5 years. The mean effective orifice area was 1.7 ± 0.5 cm2 at discharge and 1.6 ± 0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6% ± 2.9% and 96.8% ± 1.6% at 1 year (113 patients at risk) and 77.0% ± 7.5% and 93.8% ± 4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4% ± 1.9% at 1 year and 95.4% ± 6.1% at 5 years. No structural valve deterioration occurred during the follow-up period.ConclusionsThe sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Thoracic and Cardiovascular Surgery - Volume 148, Issue 4, October 2014, Pages 1681–1687
نویسندگان
, , , , , , , ,