کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2981515 1578630 2012 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The “no-dissection” technique is safe for reoperative aortic valve replacement with a patent left internal thoracic artery graft
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
The “no-dissection” technique is safe for reoperative aortic valve replacement with a patent left internal thoracic artery graft
چکیده انگلیسی

ObjectiveManagement of a patent left internal thoracic artery graft during reoperation is controversial. The “no-dissection” technique avoids dissection and clamping of the left internal thoracic artery graft, and myocardial protection is achieved using adjunctive systemic hypothermia and hyperkalemia. We compared the postoperative outcomes after isolated reoperative aortic valve replacement in patients with previous coronary artery bypass grafting with a patent left internal thoracic artery graft using a no-dissection technique with the outcomes of patients with previous coronary artery bypass grafting without a left internal thoracic artery graft.MethodsThe outcomes were analyzed for patients who underwent isolated reoperative aortic valve replacement with previous coronary artery bypass grafting from January 1, 2002, to June, 30, 2011. Patency of the left internal thoracic artery was confirmed using either coronary angiography or computed tomography angiography. The patent left internal thoracic artery group did not undergo dissection or clamping of the left internal thoracic artery graft, and myocardial protection was obtained using systemic hypothermia and hyperkalemia. The no left internal thoracic artery group underwent isolated aortic valve replacement with previous coronary artery bypass grafting but had no left internal thoracic artery graft.ResultsA total 174 patients were identified for the patent left internal thoracic artery group and 26 for the no left internal thoracic artery group. The perfusion and crossclamp times were similar. No differences were seen between the 2 groups in operative mortality (6.9% vs 7.7%, P = 1.00). The complication rates were similar, and the peak creatine kinase-MB values within 24 hours of surgery were not significantly different between the 2 groups (median, 27.4 vs 29 μ/mL; P = .72).ConclusionsReoperative aortic valve replacement in patients with previous coronary artery bypass grafting and a patent left internal thoracic artery graft can be performed safely without dissection or clamping of the left internal thoracic artery using systemic hyperkalemia and hypothermia. We believe this method prevents unnecessary injury during dissection of the left internal thoracic artery graft.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Thoracic and Cardiovascular Surgery - Volume 144, Issue 5, November 2012, Pages 1036–1041
نویسندگان
, , , , , ,