کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2982739 1578682 2008 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Left ventricular assist device as bridge to transplantation does not adversely affect one-year heart transplantation survival
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Left ventricular assist device as bridge to transplantation does not adversely affect one-year heart transplantation survival
چکیده انگلیسی

ObjectiveLeft ventricular assist devices are increasingly used as a bridge to transplantation. It remains unclear whether the use of pretransplant left ventricular assist devices adversely affects short-term survival after cardiac transplantation.MethodsA retrospective review of 317 consecutive patients undergoing cardiac transplantation at an academic center between 1986 and 2006 was undertaken. Left ventricular assist devices were used pretransplant in 23 of these 317 patients, and 294 patients did not require left ventricular assist device support. Patients with a left ventricular assist device were supported with a Heartmate VE or Heartmate XVE (Thoratec Corp, Pleasanton, Calif). Kaplan–Meier survival estimates were compared between the left ventricular assist device group and the non-left ventricular assist device group using the log-rank test. In addition, occurrence of death was analyzed between the 2 groups with a chi-square analysis. The results are expressed as 1-year survival with 95% confidence intervals in parentheses.ResultsThe 1-year survival for all 317 patients was 0.86 (0.82–0.90). The patient survival for the group without a left ventricular assist device before cardiac transplant was 0.87 (0.83–0.90), and the survival for the group with a left ventricular assist device as bridge to transplantation was 0.83 (0.67–0.98; P = .77). For the deaths that occurred in all 317 patients, 19% of the patients without left ventricular assist devices died within 30 days of transplant, whereas 80% of the patients with left ventricular assist devices died within 30 days of transplant (P < .01).ConclusionWhen used as a bridge to transplantation, left ventricular assist devices do not compromise 1-year survival after cardiac transplantation. Of the patients who die after transplantation, patients bridged with left ventricular assist devices are at higher risk for death within 30 days of transplant. These data suggest that left ventricular assist devices as a bridge to transplantation should be considered for appropriately selected patients awaiting cardiac transplantation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Thoracic and Cardiovascular Surgery - Volume 136, Issue 3, September 2008, Pages 774–777
نویسندگان
, , , , , , , , , , , ,