کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2982865 1578652 2011 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effects of different annuloplasty ring types on mitral leaflet tenting area during acute myocardial ischemia
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Effects of different annuloplasty ring types on mitral leaflet tenting area during acute myocardial ischemia
چکیده انگلیسی

ObjectiveThe study objective was to quantify the effects of different annuloplasty rings on mitral leaflet septal-lateral tenting areas during acute myocardial ischemia.MethodsRadiopaque markers were implanted along the central septal-lateral meridian of the mitral valve in 30 sheep: 1 each to the septal and lateral aspects of the mitral annulus and 4 and 2 along the anterior and posterior mitral leaflets, respectively. Ten true-sized Carpentier-Edwards Physio, Edwards IMR ETLogix, and GeoForm annuloplasty rings (Edwards Lifesciences, Irvine, Calif) were inserted in a releasable fashion. Marker coordinates were obtained using biplane videofluoroscopy with ring inserted at baseline (RING_BL) and after 90 seconds of left circumflex artery occlusion (RING_ISCH). After ring release, another dataset was acquired before (No_Ring_BL) and after left circumflex artery occlusion (No_Ring_ISCH). Anterior and posterior mitral leaflet tenting areas were computed at mid-systole from sums of marker triangles with the midpoint between the annular markers being the vertex for all triangles.ResultsCompared with No_Ring_BL, mitral regurgitation grades and all tenting areas significantly increased with No_Ring_ISCH. Compared with No_Ring_ISCH, (1) all rings significantly prevented mitral regurgitation and reduced all tenting areas; (2) Edwards IMR ETLogix and GeoForm rings reduced posterior mitral leaflet area, but not anterior mitral leaflet tenting area, to a significantly greater extent than the Carpentier-Edwards Physio ring; and (3) Edwards IMR ETLogix and GeoForm rings affected tenting areas similarly.ConclusionsIn response to acute left ventricular ischemia, disease-specific functional/ischemic mitral regurgitation rings (Edwards IMR ETLogix, GeoForm) more effectively reduced posterior mitral leaflet area, but not anterior mitral leaflet tenting area, compared with true-sized physiologic rings (Carpentier-Edwards Physio). Despite its radical 3-dimensional shape and greater amount of mitral annular septal-lateral downsizing, the GeoForm ring did not reduce tenting areas more than the Edwards IMR ETLogix ring, suggesting that further reduction in tenting areas in patients with FMR/IMR may not be effectively achieved on an annular level.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Thoracic and Cardiovascular Surgery - Volume 141, Issue 2, February 2011, Pages 345–353
نویسندگان
, , , , , , ,