کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2985105 1578685 2008 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Stereoscopic vision display technology in real-time three-dimensional echocardiography-guided intracardiac beating-heart surgery
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Stereoscopic vision display technology in real-time three-dimensional echocardiography-guided intracardiac beating-heart surgery
چکیده انگلیسی

ObjectiveStereoscopic vision display technology has been shown to be a useful tool in image-guided surgical interventions. However, the concept has not been applied to 3-dimensional echocardiography-guided cardiac procedures. We evaluated stereoscopic vision display as an aid for intracardiac navigation during 3-dimensional echocardiography-guided beating-heart surgery in a model of atrial septal defect closure.MethodsAn atrial septal defect (6 mm) was created in 6 pigs using 3-dimensional echocardiography guidance. The defect was then closed using a catheter-based patch delivery system, and the patch was attached with tissue mini-anchors. Stereoscopic vision was generated with a high-performance volume renderer with stereoscopic glasses. Three-dimensional echocardiography with stereoscopic vision display was compared with 3-dimensional echocardiography with standard display for guidance of surgical repair. Task performance measures for each anchor placement (N = 32 per group) were completion time, trajectory of the tip of the anchor deployment device, and accuracy of the anchor placement.ResultsThe mean time of the anchor deployment for stereoscopic vision display group was shorter by 44% compared with the standard display group: 9.7 ± 0.9 seconds versus 17.2 ± 0.9 seconds (P < .001). Trajectory tracking of the anchor deployment device tip demonstrated greater navigational accuracy measured by trajectory deviation: 3.8 ± 0.7 mm versus 6.1 ± 0.3 mm, 38% improvement (P < .01). Accuracy of anchor placement was not significantly different: 2.3 ± 0.3 mm for the stereoscopic vision display group versus 2.3 ± 0.3 mm for the standard display group.ConclusionStereoscopic vision display combined with 3-dimensional echocardiography improved the visualization of 3-dimensional echocardiography ultrasound images, decreased the time required for surgical task completion, and increased the precision of instrument navigation, potentially improving the safety of beating-heart intracardiac surgical interventions.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Thoracic and Cardiovascular Surgery - Volume 135, Issue 6, June 2008, Pages 1334–1341
نویسندگان
, , , , , , ,