کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2985396 1578691 2007 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
FloWatch versus conventional pulmonary artery banding
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
FloWatch versus conventional pulmonary artery banding
چکیده انگلیسی

ObjectiveWe sought to compare the efficacy of conventional pulmonary artery banding with that of FloWatch pulmonary artery banding.MethodsForty consecutive infants underwent conventional pulmonary artery banding (n = 20; mean age, 1.8 ± 1.5 months; mean weight, 3.7 ± 0.7 kg) or FloWatch pulmonary artery banding (n = 20; mean age, 2.6 ± 1.3 months; mean weight, 4.1 ± 0.8 kg). Indications were preparation for biventricular repair in 16 of 20 infants, univentricular repair in 2 of 20 infants, and left ventricular retraining in 2 of 20 infants in the conventional pulmonary artery banding group versus 13 of 20, 5 of 20, and 2 of 20 infants, respectively, in the FloWatch pulmonary artery banding group. Twelve of 20 infants required preoperative mechanical ventilation in the conventional pulmonary artery banding group (mean duration, 3.3 ± 4.3 days) versus preoperative mechanical ventilation required by 14 of 20 in the FloWatch pulmonary artery banding group (mean duration, 17.5 ± 19.0 days; P < .005).ResultsThere were 3 early and 2 late deaths after conventional pulmonary artery banding (mean follow-up, 10.8 ± 9.6 months; range, 1–33 months) versus no early and 2 late deaths after FloWatch pulmonary artery banding (mean follow-up, 13.4 ± 10.4 months; range, 1–38 months). Postoperative mechanical ventilation and intensive care unit and hospital stays were significantly longer after conventional pulmonary artery banding than those after FloWatch pulmonary artery banding, respectively (10.4 ± 11.2 vs 3.0 ± 3.1 days [P < .01], 20.3 ± 19.9 vs 5.3 ± 4.6 days [P < .005], and 45.6 ± 41.6 vs 15.4 ± 6.4 days [P < .005]). Reoperation to adjust the band was required in 7 (35%) of 20 infants after conventional pulmonary artery banding, whereas no reoperations were required after FloWatch pulmonary artery banding (P < .005). Average cost of stay in the intensive care unit and hospital was, respectively, $45,000 and $45,300 cheaper with FloWatch pulmonary artery banding than average cost with conventional pulmonary artery banding, largely surpassing the cost of the device ($10,000).ConclusionsFloWatch pulmonary artery banding appears superior to conventional pulmonary artery banding because (1) reoperations are not required; (2) postoperative management is simplified and postoperative mechanical ventilation, stay in the intensive care unit, and stay in the hospital are significantly reduced; and (3) the reduction in costs of postoperative mechanical ventilation, stay in the intensive care unit, and stay in the hospital significantly outweigh the cost of the device.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Thoracic and Cardiovascular Surgery - Volume 134, Issue 6, December 2007, Pages 1413–1420
نویسندگان
, , , ,