کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2988089 1179813 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Standard endovascular treatment of abdominal aortic aneurysms in patients with very short proximal necks using the Endurant stent graft
ترجمه فارسی عنوان
درمان آندواسکولین استاندارد آنوریسم های آئورت شکمی در بیماران مبتلا به گردن بسیار کوتاه با استفاده از پیوند سنت اندورنت
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی

ObjectiveThis study evaluated and compared the midterm results of endovascular aortic aneurysm repair with the Endurant (Medtronic Inc, Santa Rosa, Calif) stent graft system in off-label use in patients with short (<10 mm) proximal aortic necks and in patients treated according to device-specific instructions for use.MethodsThis was a case-control (2:1) single-center retrospective analysis of prospectively collected data performed between September 2008 and December 2012. Analysis identified 19 elective patients with short (<10 mm) proximal necks and mild angulations (≤45°) treated with the Endurant stent graft and 38 patients matched for age, sex, and aneurysm diameter with proximal aortic necks ≥10 mm in length who met the instructions for use. End points included technical and clinical success and freedom from any secondary intervention, any type of endoleak, and aneurysm-related death.ResultsThe short-neck group was a mean ± standard deviation age of 71.7 ± 8.9 years, 84% were men, and their mean infrarenal aortic neck length was 6.1 ± 1.2 mm. Mean suprarenal and infrarenal angles were 110° ± 10.4° and 170° ± 15.4°, respectively. Aortic neck diameters were similar between the groups (26.6 ± 3.8 vs 25.7 ± 3.7 mm; P = .36). Primary technical success was achieved in all cases. Off-label patients were more likely to require additional proximal cuff deployment to successfully obtain a seal (21% vs 3%; P = .04). The two patient groups were similar in rates of perioperative mortality, morbidity, and complications. Mean follow-up of 24 ± 12 months revealed no differences in clinical success, freedom from reintervention, and aneurysm-related death. No type I endoleaks were observed in either group during the follow-up period.ConclusionsThe Endurant stent graft system applied off-label in patients with very short aneurysm necks (<10 mm) with mild angulation showed acceptable treatment results. These midterm results might suggest its use in carefully selected patients with very short neck anatomy. Long-term data are needed to verify the observed durability of the Endurant stent graft.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Vascular Surgery - Volume 61, Issue 1, January 2015, Pages 9–15
نویسندگان
, , , , , , ,