کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2988270 1179819 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation of the Zenith low-profile abdominal aortic aneurysm stent graft
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Evaluation of the Zenith low-profile abdominal aortic aneurysm stent graft
چکیده انگلیسی

BackgroundLow-profile (LP) stent grafts are now commercially available in Europe for endovascular aortic aneurysm repair (EVAR). In this study the midterm outcomes and characteristics of patients treated with this last generation of stent grafts were compared with a cohort of patients treated with “standard-profile” (SP) stent grafts.MethodsThe current study enrolled all patients treated for elective EVAR by the SP Zenith Flex stent graft (Cook Medical, Bloomington, Ind) between March 2010 and November 2011 and patients treated for elective EVAR by the Zenith LP stent graft (Cook Medical) between November 2011 and March 2013. All patients had a follow-up >18 months. Preoperative computed tomography angiograms were analyzed on a dedicated three-dimensional workstation. All data were prospectively collected in an electronic database and retrospectively analyzed. A comparative study was conducted.ResultsThe present study included 208 patients (107 SP and 101 LP). Patients' physiologic characteristics were similar in both groups. The iliac anatomy was considered “more challenging” in LP patients: respectively, 7% and 22% (P = .002) of SP and LP patients had bilateral external iliac diameter <7 mm; and 16% and 34% (P = .005) had a combination of an external iliac diameter <7 mm and an iliac tortuosity ratio index >1.5. No 30-day deaths were documented. The 24-month freedom from reintervention and overall survival rates after SP and LP were, respectively, 88% and 91% (P = .450) and 92% and 96% (P = .153). The 24-month rates for freedom from sac expansion and from limb occlusion were 96.4% and 98.7% (P = .320) and 92% and 95% (P = .293), respectively. One patient in each group presented with a type I endoleak during follow-up, and two LP patients presented with a type III endoleak (P = .235).ConclusionsThis study demonstrates that the last-generation LP stent grafts have favorable midterm outcomes similar to SP stent grafts despite being used to treat more patients with unfavorable iliac anatomy.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Vascular Surgery - Volume 62, Issue 4, October 2015, Pages 841–847
نویسندگان
, , , , , , , ,