Performance of the Endurant stent graft in patients with abdominal aortic aneurysms independent of their morphologic suitability for endovascular aneurysm repair based on instructions for use
ترجمه فارسی عنوان
عملکرد غربالگری استنت گیرنده در بیماران مبتلا به آنوریسم های آئورت شکمی مستقل از مناسب بودن مورفولوژی آنها برای ترمیم آندوسکوپی آنوریسمی بر اساس دستورالعمل های استفاده از
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی

ObjectiveThe aim of this study was to prospectively evaluate the early and late 7-year experience with the Endurant bifurcated stent graft system (Medtronic, Santa Rosa, Calif) in patients with abdominal aortic aneurysms.MethodsBetween November 14, 2007, and December 2013, 712 consecutive high-risk patients with abdominal aortic aneurysms underwent elective or urgent placement of an Endurant bifurcated endograft in our institution. The included patients were consecutive (all comers) and treated independently from their morphologic eligibility for use of the Endurant device based on the instructions for use. The primary study outcome was freedom from all-cause reintervention.ResultsThe median follow-up was 19.2 months (interquartile range, 6.3-35.9 months). Overall, 517 patients (72.6%) were treated on the basis of instructions for use conditions. On the other hand, 195 patients (27.4%) had morphologic data not consistent with the recommendations for the use of the Endurant system. The 30-day mortality was 1.4% (10 of 712). Nine patients (1.2%) were lost to follow-up because of relocation abroad. The overall mortality rate was 14.74% (101 of 703). Overall survival rate was 92.3% at 1 year, 86.4% at 2 years, and 65% at 5 years. Overall freedom from reintervention rate was 93.3%, 86.4%, and 65% at 1 year, 2 years, and 5 years, respectively. Five patients (0.7%) underwent a surgical conversion and explantation of the Endurant device. The reasons were endograft infection (n = 1), endoleak type Ia (n = 1), endoleak type II (n = 1), endograft and limb thrombotic occlusion (n = 1), and endotension (n = 1). The overall iliac limb occlusion rate was 2.1% (15 of 712).ConclusionsThe performance of the Endurant stent graft during a period of 7 years under real-life conditions was good, with low incidence of reinterventions and endoleaks.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Vascular Surgery - Volume 62, Issue 4, October 2015, Pages 848–854
نویسندگان
, , , , , ,