کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2991014 1179862 2012 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Remodeling of proximal neck angulation after endovascular aneurysm repair
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Remodeling of proximal neck angulation after endovascular aneurysm repair
چکیده انگلیسی

ObjectiveThis study investigated the remodeling of proximal neck (PN) angulations of abdominal aortic aneurysms (AAAs) after endovascular aneurysm repair (EVAR).MethodsA 64-row multidetector computed tomography scan of AAAs treated with EVAR was reviewed, and the PN angulation was measured on a volume-rendered three-dimensional image. The computed tomography scan was examined preoperatively, after EVAR at 1 week, 1 month, 6 months, 1 year, 1.5 years, 2 years, and then yearly. The study enrolled 78 patients, comprising 54 Zenith devices (Cook Medical, Bloomington, Ind) and 24 Excluder devices (W. L. Gore and Associates, Flagstaff, Ariz).ResultsPN angulation was 50° ± 20° preoperatively, and after EVAR was 36° ± 14° at 1 week, 32° ± 14° at 1 year, and 28° ± 13° at 3 years. PN angulations ≤60° (n = 70, 77%) were 41° ± 13° preoperatively, 31° ± 12° 1 week after EVAR, 28° ± 12° at 1 year, and 26° ± 13° after 3 years. An angulation >60° (n = 18, 23%) was 78° ± 14° preoperatively, 51° ± 11° 1 week after EVAR, 44° ± 11° at 1 year, and 40° ± 12° after 3 years. The greater the preoperative PN angulation, the greater its reduction immediately after EVAR (r = .72, P < .001). The diameter shrinkage of AAAs with a PN angulation >60° was 3 ± 6 mm after 1 year; a significantly smaller shrinkage than with a PN angulation ≤60° (7 ± 7 mm, P < .05). AAAs with a PN angulation >60° had a larger angulation reduction and a smaller diameter shrinkage after the EVAR procedure. The PN angulation of the 54 AAAs treated by Zenith was 49° ± 22° preoperatively, 34° ± 14° 1 week after EVAR, and 25° ± 13° after 3 years. The corresponding angulation of the 24 AAAs treated by Excluder devices was 52° ± 17°, 41° ± 14°, and 38° ± 9°, respectively. The PN angulation reduction of Zenith and Excluder was similar 1 week after the EVAR procedure. Unlike Excluder, however, the PN angulation in Zenith continued to reduce for a long period at a slow pace. There were no significant correlations between PN angulation reduction and diameter change and between PN length and diameter change (P = .86 and .18, respectively).ConclusionsAlthough the instructions for use of most commercially available stent grafts provide for a PN angulation of ≤60°, PN angulation was not a major issue in a midterm follow-up of AAAs with adequate PN length for patients in this series who received a Zenith or Excluder graft.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Vascular Surgery - Volume 56, Issue 5, November 2012, Pages 1201–1205
نویسندگان
, , , , , , , ,