کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
299967 512465 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluating the optimum load range for box-type solar cookers
ترجمه فارسی عنوان
ارزیابی محدوده بار بهینه برای صفحات خورشیدی جعبه خورشیدی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی


• For each solar cooker there exists a load range for that cooker preferably shows good thermal as well as good cooking performance.
• This load range is called as optimum load range (OLR).
• The theoretical explanation of existence of OLR has been given.
• On-field studies of a solar cooker named SFSC strengthen the concept of OLR.
• OLR may be considered a crucial parameter for solar cookers.

This paper introduces a new concept of Optimum Load Range (OLR) for solar cookers. OLR gives the load values for which cooker preferably shows good thermal as well as good cooking performance; it may be considered a crucial parameter for solar cookers. This OLR concept is based on the dependence of rate of rise of load temperature on different heat transfer processes between load and cooker interior. This concept illustrates solar cooking in two simple steps. The total time required to complete these steps puts an essential constraint for cooking of any load amount. The maximum value of load (upper limit of OLR) till which cooker shows satisfactory cooking may be determined from this constraint. This constraint requires determination of two OLR parameters which are tstep I and tstep II. The load for which cooker remain almost 30% efficient, may be referred as lower limit (minimum value) of OLR. For the verification of OLR, experimental studies have been conducted with a solar cooker named SFSC. The OLR parameters along with different thermal performance parameters (TPPs) (second figure of merit (F2), utilization efficiency (ηu) etc.) suggested by different researches for solar cookers in water load condition have been computed from the measured thermal profiles of different loads (0.8–3.0 kg). From the curve analysis of different TPPs with load, the existence of upper limit of OLR is observed. The values of rate of rise of load temperature at water temperatures 80, 85 and 90 °C for different loads also confirm the same. The OLR of SFSC is found to be 1.2–1.6 kg.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Renewable Energy - Volume 74, February 2015, Pages 187–194
نویسندگان
, , , , ,