کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3009952 1181503 2010 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation of the Neonatal Resuscitation Program's recommended chest compression depth using computerized tomography imaging
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Evaluation of the Neonatal Resuscitation Program's recommended chest compression depth using computerized tomography imaging
چکیده انگلیسی

BackgroundNeonatal Resuscitation Program (NRP) guidelines recommend chest compression depths of 1/3 the anterior–posterior (AP) chest depth. Appropriateness of this recommendation has not been rigorously assessed.ObjectiveTo compare the efficacy and safety of neonatal chest compression depths of 1/4, 1/3, and 1/2 AP chest depth during cardiopulmonary resuscitation.Design/methodsAnterior–posterior internal and external chest depth, heart dimensions, and non-cardiac thoracic tissue depth were measured from neonatal chest CTs. Using these measurements, residual internal chest depth, the remaining depth of the chest between the sternum and spine after external compression, was calculated for compression depths of 1/4, 1/3 and 1/2 anterior–posterior chest depth. Compression sufficient to compress the chest to <10 mm of residual internal chest depth was defined as over-compression. Using a mathematic model, an estimated ejection fraction (EF) was calculated for each chest compression depth. Compression inadequate to obtain a predicted 50% EF was defined as under-compression. Descriptive statistics, Fisher's exact test and Student's t-test were used to analyze data, where appropriate.ResultsFifty-four neonatal chest CT scans were evaluated. Estimated chest compression induced EF increased incrementally with increasing chest compression depth (EF was 51 ± 3% with 1/4 AP chest depth vs 69 ± 3% with 1/3 AP chest depth, and 106% with 1/2 AP chest depth, p < 0.001). Under-compression was predicted in 29/54 patients with 1/4 AP compression depth, but none of the patients with 1/3 or 1/2 AP compression depth, p < 0.001. Over-compression, or lack of adequate residual chest depth, was predicted in 49/54 patients with 1/2 AP compression depth, but none of the patients with 1/4 or 1/3 AP compression depth, p < 0.001.ConclusionsMathematical modeling based upon neonatal chest CT scan dimensions suggests that current NRP chest compression recommendations of 1/3 AP chest depth should be more effective than 1/4 compression depth, and safer than 1/2 AP compression depth.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Resuscitation - Volume 81, Issue 5, May 2010, Pages 544–548
نویسندگان
, , , , , , , ,