کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3010326 1181510 2010 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Coronary blood flow and perfusion pressure during coronary angiography in patients with ongoing mechanical chest compression: A report on 6 cases
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Coronary blood flow and perfusion pressure during coronary angiography in patients with ongoing mechanical chest compression: A report on 6 cases
چکیده انگلیسی

Patients with pulseless electrical activity or refractory ventricular fibrillation have a very bad prognosis. Coronary angiography and angioplasty may be required to restore an effective circulation, but this must be performed whilst chest compressions are continued. The LUCAS chest compression device is suitable for this purpose. So far there are no reports on the effect of this device on coronary circulation in humans. We monitored the coronary perfusion pressure assessed invasively as the difference between the diastolic pressures at the coronary ostium and right atrium, and compared these pressures with coronary flow graded using the TIMI scale in 6 patients. In 4 out of 6 we found a satisfactory coronary artery perfusion pressure and TIMI grade 3 flow (normal) on coronary angiography. Two of these patients survived the first 24 h. Two patients did not have a satisfactory perfusion pressure and adequate flow rate was not seen.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Resuscitation - Volume 81, Issue 4, April 2010, Pages 493–497
نویسندگان
, , , , , ,