کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
303093 512578 2005 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The effect of absorber packing height on the performance of a hybrid liquid desiccant system
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
پیش نمایش صفحه اول مقاله
The effect of absorber packing height on the performance of a hybrid liquid desiccant system
چکیده انگلیسی

A hybrid system consisting of vapour compression unit, a liquid desiccant system, and a flat solar hot water collector were designed, fabricated and tested. This combination allowed for a separate control of humidity and temperature without energy penalty. Various packing heights of the absorber component were tested to determine the optimal performance of the combined unit. A 1000 mm packing height with cross-sectional area of 600×600 mm, proved to be the best height that gives promising improvements in the coefficient of performance of the vapour compression unit.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Renewable Energy - Volume 30, Issue 15, December 2005, Pages 2247–2256