کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
3124800 | 1583763 | 2009 | 4 صفحه PDF | دانلود رایگان |

Stainless steel wire is often used in the management of jaw fractures to provide intraoperative or postoperative intermaxillary fixation (IMF). Wiring of the jaws is time-consuming, a second procedure is needed to remove it, and needlestick injuries occur during placement.We report on 151 consecutive patients who had wire-free fixation of jaw fractures, and outline the value of a system of plastic anchorage points applied to individual teeth in both jaws that allows for wire-free IMF when they are linked by elastics (Rapid IMF™, Synthes, PA, USA).A total of 150 successive patients had wire-free fixation of 146 mandibular and 5 maxillary fractures. Ninety-eight were hand-held in occlusion, and 52 were treated using Rapid IMF™. There were few complications.
Journal: British Journal of Oral and Maxillofacial Surgery - Volume 47, Issue 7, October 2009, Pages 521–524