کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3132382 1584143 2014 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparative study between lag screw and miniplate fixation for straight midline mandibular osteotomy
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Comparative study between lag screw and miniplate fixation for straight midline mandibular osteotomy
چکیده انگلیسی

The mandibular swing approach is a surgical approach for the resection of malignant lesions localized in the posterior oral cavity and oropharynx. We analyzed 15 years of experience with fixation of the straight midline mandibulotomy and compared two fixation methods: lag screws and miniplates. A total of 117 patients underwent a straight midline mandibulotomy during the study period; 85 had fixation with two lag screws and 32 with two miniplates. The overall complication rate was low and there was no significant difference in complication rate regarding the fixation method (9% for miniplates vs. 7% for lag screws). The most serious complication over the whole study period was non union, which occurred in only two patients, followed by orocutaneous fistula and infection. Radiotherapy did not cause serious complications and is not regarded as hazardous in midline mandibulotomy patients. We conclude that lag screw fixation is at least as safe as miniplate fixation, but because of better fragment compression, offers faster bone healing.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Oral and Maxillofacial Surgery - Volume 43, Issue 4, April 2014, Pages 399–404
نویسندگان
, , , ,