چکیده انگلیسی

The aim of this study is to present a technique for maxillary distraction osteogenesis using Le Fort I osteotomy without down-fracture. Six cleft-related patients suffering from severe midfacial deficiency were treated with maxillary distraction osteogenesis. The RED II system was chosen as the extraoral device and the Leipzig retention plate system to anchor the maxillary segment. Maxillary distraction osteogenesis was successful in all cases. Cephalometric and clinical evaluation after an average follow-up period of 1 year showed stable results with respect to skeletal and dental relationships. The SNA angle increased from 72.3° to 81.4° and the ANB angle increased by 11.0° immediately after removing the distraction device. After 1 year, the sagittal bone gain remained and the SNA angle had decreased by 0.8°. This technique seems to minimize the risk of the surgical procedure and shorten the operation time. It may become an alternative method for the treatment of patients with severe midfacial hypoplasia.