کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3146792 1197317 2015 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of the Cyclic Fatigue Resistance of 5 Different Rotary Pathfinding Instruments Made of Conventional Nickel-Titanium Wire, M-wire, and Controlled Memory Wire
ترجمه فارسی عنوان
مقایسه مقاومت خستگی چرخه 5 ابزار مختلف کشش روتاری ساخته شده از سیم معمولی نیکل تیتانیوم، سیم مسی و سیم حافظه کنترل شده
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
چکیده انگلیسی


• Cyclic fatigue resistance of 5 different pathfinding instruments was evaluated in 2 different curvature radii.
• Because of the varying apical size and taper designs of the pathfinding instruments, in the present study instruments having different apical size were tested with different working lengths to get a similar instrument diameter at maximum stress point.
• HyFlex GPF had the highest performance in terms of cyclic fatigue resistance, and the ranking of the other instruments in decreasing order of fatigue resistance was as follows: G-File > ProGlider > PathFile > Scout Race.

IntroductionThis study compared the cyclic fatigue resistance of current nickel-titanium rotary path-finding instruments.MethodsFive types of nickel-titanium rotary pathfinding instruments were used in steel canals with a 90° curvature and a curvature radius of 3 mm (n = 10) and 5 mm (n = 10). The cyclic fatigue of the following instruments was tested at 4 mm from the tip: PathFile (#16 and a .02 taper; Dentsply Maillefer, Ballaigues, Switzerland), G-File (#12 and a .03 taper; Micro-Mega, Besançon Cedex, France), Scout Race (#15 and a .02 taper; FKG Dentaire, La Chaux-de-Fonds, Switzerland), HyFlex GPF (#15 and a .02 taper; Coltene-Whaledent, Allstetten, Switzerland), and ProGlider (#16 with a mean taper of .04125 and a .02 at the first 4 mm from the tip, Dentsply Maillefer). The length of the fractured parts was measured, and the number of cycles to fracture (NCF) was calculated. The data were statistically analyzed using Kruskal-Wallis and Mann-Whitney tests (α = .05). After Bonferroni correction, the new P value was set as .005.ResultsThe difference in the cyclic fatigue of all the files at both curvatures was statistically significant (P values from .0035 to less than .0001). The ranking of the instruments from the highest to the lowest NCF was as follows: HyFlex GPF, G files, ProGlider, PathFile, and Scout Race. The length of the fractured part of the instruments was similar in all the groups (P > .05). All the tested instruments had a lower NCF at a curvature radius of 3 mm when compared with a curvature radius of 5 mm (P < .0001).ConclusionsWithin the limitations of this study, the cyclic fatigue resistance of the HyFlex GPF instrument was the highest, and the curvature radius had a significant effect on the fatigue resistance.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Endodontics - Volume 41, Issue 4, April 2015, Pages 535–538
نویسندگان
, , , ,