IntroductionThe objective of the study was to evaluate the ability of large-volume cone-beam computed tomography (CBCT) to detect horizontal root fracture and to test the influence of a metallic post.MethodsThrough the examination of 40 teeth by large-volume CBCT (20-cm height and 15-cm diameter cylinder) at 0.2-mm voxel resolution, 2 observers analyzed the samples for the presence and localization of horizontal root fracture.ResultsThe values of accuracy in the groups that had no metallic post ranged from 33%–68%, whereas for the samples with the metallic post, values showed a wide variation (38%–83%). Intraobserver agreement showed no statistically significant difference between the groups with/without metallic post; both ranged from very weak to weak (kappa, 0.09–0.369).ConclusionsThe low accuracy and low intraobserver and interobserver agreement reflect the difficulty in performing an adequate diagnosis of horizontal root fractures through a large-volume CBCT by using a small voxel reconstruction.
Journal: Journal of Endodontics - Volume 38, Issue 6, June 2012, Pages 856–859