کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3147613 1585503 2014 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Accuracy of an Electronic Apex Locator in the Retreatment of Teeth Obturated with Plastic or Cross-linked Gutta-percha Carrier-based Materials: An Ex Vivo Study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Accuracy of an Electronic Apex Locator in the Retreatment of Teeth Obturated with Plastic or Cross-linked Gutta-percha Carrier-based Materials: An Ex Vivo Study
چکیده انگلیسی


• GuttaCore and ProTaper Obturators statistically influence the accuracy of Root ZX.
• GuttaCore and ProTaper Obturators do not behave differently with the electronic apex locator tested.
• Electronic measurements during orthograde retreatments can lead clinicians to overinstrumentation.
• Clinicians should subtract at least 1 mm from the working length on the “APEX” mark before shaping and sealing.
• It is essential to recalculate the working length after the complete removal of endodontic material.

IntroductionThis ex vivo study evaluated the accuracy of the Root ZX electronic apex locator (EAL) (J Morita Corp, Kyoto, Japan) in determining the working length during retreatment of canals sealed with 2 different carrier-based obturating materials (ProTaper Obturator [Dentsply Maillefer, Ballaigues, Switzerland] and GuttaCore [Dentsply Maillefer]) and also evaluated whether they influenced its accuracy differently.MethodsFifty extracted single-rooted human teeth with sound apices were selected for the study. We measured canals with the direct visual technique using a #10 K-file and shaped them with ProTaper Universal instruments (Dentsply Maillefer) up to this predetermined length. After instrumentation, we determined the canal length again using the visual technique (direct length [DL]). This value was considered the “reference point.” Specimens were then placed in a tooth holder (Pro-Train; Simit Dental, Mantova, Italy), and the canal length was electronically measured (electronic length 1 [EL1]). Specimens were then obturated with ProTaper Obturators (group 1, n = 25) and GuttaCore (group 2, n = 25). Seven days later, a new electronic length was determined (electronic length 2 [EL2]) during retreatment procedures in the presence of the obturating material. EL1 and EL2 values were compared with DL using the Bland and Altman method. The different influences of the tested materials on the accuracy of the EAL were calculated with repeated measures analysis of variance.ResultsBoth EL1 and EL2 values provided a statistically significant overestimation of the actual canal length (DL [P < .05]), with the EL2 values higher from DL. The 2 different materials did not influence the accuracy of the EAL differently (P = .486).ConclusionsThe measurements obtained with the EAL tested during orthograde retreatments can lead clinicians to overinstrumentation and consequent overfilling of the endodontic space.