کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
3147766 | 1197375 | 2014 | 4 صفحه PDF | دانلود رایگان |
IntroductionThis study aimed to evaluate the frequency of dentinal microcracks observed after root canal preparation with 2 reciprocating and a conventional full-sequence rotary system using micro–computed tomographic analysis.MethodsThirty mesial roots of mandibular molars presenting a type II Vertucci canal configuration were scanned at an isotropic resolution of 14.16 μm. The sample was randomly assigned to 3 experimental groups (n = 10) according to the system used for the root canal preparation: group A—Reciproc (VDW, Munich, Germany), group B—WaveOne (Dentsply Maillefer, Baillagues, Switzerland), and group C—BioRaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland). Second and third scans were taken after the root canals were prepared with instruments sizes 25 and 40, respectively. Then, pre- and postoperative cross-section images of the roots (N = 65,340) were screened to identify the presence of dentinal defects.ResultsDentinal microcracks were observed in 8.72% (n = 5697), 11.01% (n = 7197), and 7.91% (n = 5169) of the cross-sections from groups A (Reciproc), B (WaveOne), and C (BioRaCe), respectively. All dentinal defects identified in the postoperative cross-sections were also observed in the corresponding preoperative images.ConclusionsNo causal relationship between dentinal microcrack formation and canal preparation procedures with Reciproc, WaveOne, and BioRaCe systems was observed.
Journal: Journal of Endodontics - Volume 40, Issue 9, September 2014, Pages 1447–1450