کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3148188 1197390 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation of the Effect of Needle Position on Irrigant Flow in the C-shaped Root Canal Using a Computational Fluid Dynamics Model
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Evaluation of the Effect of Needle Position on Irrigant Flow in the C-shaped Root Canal Using a Computational Fluid Dynamics Model
چکیده انگلیسی


• The C-shaped canal is complex and often includes lateral canals and isthmuses, and because the root cannot be disassembled for evaluation, it is difficult to study the effectiveness of irrigation in C-shaped canals.
• The study investigates the effect of the orientation of a side-vented needle on the irrigant flow pattern in a C-shaped root canal system by using computational fluid dynamics and evaluates the real-time replacement of the irrigant in the canal.
• A human mandibular second molar with a C-shaped root canal and a lateral canal imaged by micro–computed tomographic imaging as used in this study is applicable for defining the fluid flow domain for computational fluid dynamics analysis of endodontic irrigation.

IntroductionThe purpose of this study was to investigate the effect of the orientation of a side-vented needle on the irrigant flow pattern in a C-shaped root canal system using computational fluid dynamics and to evaluate the real-time replacement of irrigant in the lateral canal (LC).MethodsA mandibular second molar with a complete C-shaped canal system was chosen for this study. The root canals were prepared and scanned, and then the images were exported to design software. A 30-G, side-vented irrigation needle was positioned with the open notch facing the lateral canal (case A) and rotated 90°, 180°, and 270° clockwise (cases B, C, and D, respectively). The flow pattern, irrigant replacement, velocity distribution, wall stress distribution, and apical pressure in the canal were analyzed.ResultsMost of the irrigant flowed to the canal outlet from the adjacent instrumented canal space with different trajectories in the 4 cases. The concentration of scalar immediately below the tip of the needle was exchanged quickly; the length of the cleared zone extended 3 mm beyond the tip of the needles. The depth of circulation in the LC in all cases increased during the first 0.2 seconds. After that, the exchange of irrigant reached a stable phase. Irrigant penetration in the LC was greatest in cases A and B (<1.1 mm). Apical pressure in case B was significantly lower than in other groups.ConclusionsThe scalar concentration can be used to evaluate the replacement of irrigant in the root canal over time. Orientation of the opening of the side-vented needle influences the flow pattern, velocity, apical wall pressure, and penetration into the LC.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Endodontics - Volume 41, Issue 6, June 2015, Pages 931–936
نویسندگان
, , , , , , ,