کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3148944 1197426 2012 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Canal Shaping with WaveOne Primary Reciprocating Files and ProTaper System: A Comparative Study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Canal Shaping with WaveOne Primary Reciprocating Files and ProTaper System: A Comparative Study
چکیده انگلیسی

IntroductionThis study compared the canal curvature and axis modification after instrumentation with WaveOne Primary reciprocating files (Dentsply Maillefer, Ballaigues, Switzerland) and nickel-titanium (NiTi) rotary ProTaper (Dentsply Maillefer).MethodsThirty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer) were used. In all specimens, the glide path was achieved with PathFile 1, 2, and 3 (Dentsply Maillefer) at the working length (WL). Specimens were then assigned to 1 of 2 groups for shaping: specimens in group 1 were shaped with ProTaper S1-S2-F1-F2 at the WL and specimens in group 2 were shaped with WaveOne Primary reciprocating files at the WL. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b (The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio (CRr) and the relative axis error (rAe), representing canal curvature modification. Data were analyzed with one-way balanced analyses of variance at 2 levels (P < .05).ResultsThe instrument factor was extremely significant for both the CRr parameter (F1 = 9.59, P = .004) and the rAe parameter (F1 = 13.55, P = .001).ConclusionsCanal modifications are reduced when the new WaveOne NiTi single-file system is used.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Endodontics - Volume 38, Issue 4, April 2012, Pages 505–509
نویسندگان
, , , , , , ,