کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3150053 1197492 2016 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Percentage of Gutta-percha Filled Areas in Canals Obturated with Cross-linked Gutta-percha Core-carrier Systems, Single-Cone and Lateral Compaction Technique
ترجمه فارسی عنوان
درصد کانال های پر شده با گوتاپرکا در کانال ها با سیستم های حامل هسته گوتاپرکا متقابل، تکنیک تک تیرگی و تراکم جانبی
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
چکیده انگلیسی


• Quality of obturation using GuttaCore/GuttaFusion in relation to instrument used was studied.
• Percentage of void-free specimens was determined and compared to other obturation techniques.
• The type of instrument used for canal preparation had no impact on the quality of obturation.
• The new cross-linked core-carrier systems produced obturations with a low incidence of voids.

IntroductionThe aim of this study was to compare different obturation techniques in terms of the percentage of gutta-percha filled areas (PGFA), sealer filled areas (PSFA), and voids in straight root canals prepared with different instruments.MethodsOne hundred sixty extracted single-rooted mandibular premolars with straight canals were allocated into 10 groups (n = 16 teeth per group): A, manual instrumentation + lateral compaction (LC); B, Mtwo + GuttaFusion (GF); C, Mtwo + LC; D, Mtwo + single-cone (SC); E, Reciproc + GF; F, Reciproc + LC; G, Reciproc + SC; H, WaveOne + GuttaCore (GC); I, WaveOne + LC; and J, WaveOne + SC. Apical preparation was size 40 in all groups, and AH Plus was used as a sealer. The teeth were sectioned at 2, 4, 6, and 8 mm from the apex. The total area of each canal segment was measured, and the areas were converted to PGFA, PSFA, and voids. Data were subjected to the Kruskal-Wallis and post hoc Dunn tests.ResultsAt the 2-mm level, no significant differences in terms of PGFA and PSFA were obtained (P > .05). At all other levels, canals filled with GC and GF produced significantly higher PGFA and significantly lower PSFA than all other groups (P < .05). At the 2-mm, 4-mm, and 6-mm levels, canals filled with GC and GF showed less voids than group A (P < .05).ConclusionsUnder the conditions of this study, independent of the instrument used for canal preparation, GuttaCore and GuttaFusion produced very homogenous root canal fillings with high PGFA and a low incidence of voids.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Endodontics - Volume 42, Issue 2, February 2016, Pages 294–298
نویسندگان
, , , ,