کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3150329 1197512 2015 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of Different Dentin Pretreatment Protocols on the Bond Strength of Glass Fiber Post Using Self-etching Adhesive
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Comparison of Different Dentin Pretreatment Protocols on the Bond Strength of Glass Fiber Post Using Self-etching Adhesive
چکیده انگلیسی


• We evaluated different dentin pretreatment on the bond strength.
• The use of ultrasound or laser irradiation showed no improvement in bond strength.
• The use of NaOCl decreased the bond strength, whereas chlorhexidine preserved it.

IntroductionThis study compared the influence of different irrigants with and without ultrasound or laser irradiation on the bond strength of glass fiber posts using a self-etching adhesive in a supplementary dentin pretreatment.MethodsNinety bovine incisor roots were divided into 3 groups according to the irrigant tested: 2% chlorhexidine (CHX) (n = 30); 2.5% sodium hypochlorite (NaOCl) (n = 30), and saline solution (control) (n = 30). Each group was randomly divided into 3 subgroups according to the supplementary dentin pretreatment: ultrasound, Nd:YAG laser, and nonsupplemented (control). A self-etching adhesive system (Futurabond DC; VOCO GmbH, Cuxhaven, Germany) was used, and the glass fiber posts were cemented with dual-cure epoxy-based luting agent (Bifix QM, VOCO GmbH). All roots were sectioned transversely, and the push-out test was performed. Failure mode analysis was also evaluated.ResultsBond strength decreased significantly after the use of 2.5% NaOCl in all root thirds (P < .05). CHX showed no difference in the mean bond strength value compared with saline solution (P > .05). The supplementary dentin pretreatment using the Nd:YAG laser or ultrasound did not improve the bond strength values for both NaOCl and CHX (P > .05). Moreover, the apical third exhibited the lowest mean bond strength values (P < .05). Analysis indicated that the predominant failure mode was the mixed type.ConclusionsRegardless of the irrigant used, the supplementary dentin pretreatment with ultrasound or laser irradiation showed no improvement in bond strength. Also, the use of NaOCl decreased the bond strength of glass fiber posts using a self-etching adhesive system, whereas CHX preserved it.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Endodontics - Volume 41, Issue 1, January 2015, Pages 83–87
نویسندگان
, , , , , , , ,