3226472 | 1588156 | 2010 | 4 صفحه PDF | دانلود رایگان |

BackgroundEnd-tidal carbon dioxide pressure (etCO2) is widely used in anaesthesia and critical care in intubated patients. The aim of our preliminary study was to evaluate the feasibility of a simple device to predict capnia in spontaneously breathing patients in an emergency department (ED).Patients and methodsThis study was a prospective, nonblind study performed in our teaching hospital ED. We included nonintubated patients with dyspnea (≥18 years) requiring measurement of arterial blood gases, as ordered by the emergency physician in charge. There were no exclusion criteria. End-tidal CO2 was measured by an easy-to-use device connected to a microstream capnometer, which gave a continuous measurement and graphical display of the etCO2 level of a patient's exhaled breath.ResultsA total of 43 patients (48 measurements) were included, and the majority had pneumonia (n = 12), acute cardiac failure (n = 8), asthma (n = 7), or chronic obstructive pulmonary disease exacerbation (n = 6). Using simple linear regression, the correlation between etCO2 and Paco2 was good (R = 0.82). However, 18 measurements (38%) had a difference between etCO2 and Paco2 of 10 mm Hg or more. The mean difference between the Paco2 and etCO2 levels was 8 mm Hg. Using the Bland and Altman matrix, the limits of agreement were −10 to +26 mm Hg.ConclusionIn our preliminary study, etCO2 using a microstream method does not seem to accurately predict Paco2 in patients presenting to an ED for acute dyspnea.
Journal: The American Journal of Emergency Medicine - Volume 28, Issue 6, July 2010, Pages 711–714