BackgroundLesion detection rate during colonoscopy may be influenced by the endoscopist's experience. EPK-i system colonoscopy (i-Scan) can improve mucosal and vascular visualization for detecting lesions.AimTo compare mucosal lesions detection rate and the withdrawal time of the instrument among non-expert and expert endoscopists.MethodsColonoscopy records of all consecutive patients undergoing first HD+ with i-Scan- or SWL-equipped colonoscopy for colorectal cancer screening over a twelve-month period were evaluated, in a “post hoc” analysis.Results542 colonoscopies (389 HD+ with i-Scan; 153 SWL): expert and non-expert endoscopists did respectively 272 and 117 HD+ with i-Scan and 83 and 70 SWL colonoscopies. Expert endoscopists did more i-Scan colonoscopies than non-experts (p = 0.006). In the SWL procedures, the experts detected mucosal lesions in more colonoscopies than non-experts (61/22 vs. 23/47, p = 0.0001) and found a significantly higher mean number of lesions (1.34 vs. 0.47; p = 0.0001). Experts detected more or less the same mean number of lesions with both imaging techniques, while among non-experts detection with HD+ with i-Scan was significantly better than with SWL imaging (1.39 vs. 0.47; p = 0.0001).ConclusionsHD+ with i-Scan imaging enables less skilled endoscopists to achieve results comparable to those of experienced ones in detecting mucosal lesions.
Journal: Digestive and Liver Disease - Volume 45, Issue 6, June 2013, Pages 481–486