کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
3263538 | 1207762 | 2010 | 5 صفحه PDF | دانلود رایگان |
BackgroundStandardization of the 13C-octanoic acid breath test is still lacking.AimTo evaluate the accuracy of the 13C-octanoic acid breath test using a new standardized ready-to-eat, gluten-, glucose-, and lactose-free muffin.MethodsHealthy subjects were recruited and sorted by sex and age. Patients with diabetic gastroparesis and untreated celiac disease with known gastric motility disorders were also tested with the new labelled muffin. Expired breath 13CO2 was analysed and t1/2 was calculated.ResultsOverall, 131 healthy subjects were enrolled. The reference range of t1/2 was 88 ± 29 min with the value of 146 min as the upper limit of normal range. No significant difference in t1/2 was found among subjects sorted by sex or age. The within-subject variability of t1/2 was 17%. Mean (±standard deviation) t1/2 values were 179 ± 50 min in patients with diabetic gastroparesis (n = 8) and 151 ± 20 min in those with untreated celiac disease (n = 11) (p ≤ 0.001 vs controls).ConclusionsA new standardized test meal simplifies the execution of the 13C-octanoic acid breath test, is not influenced by sex or age, has low intra-individual variability, is palatable, does not cause side effects, and is able to evaluate gastric emptying in both patients and healthy controls. Moreover, it can be used in subjects with lactose intolerance, diabetes, and celiac disease.
Journal: Digestive and Liver Disease - Volume 42, Issue 8, August 2010, Pages 549–553