کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3301885 1210282 2016 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Novel intragastric trocar placed by PEG technique permits endolumenal use of rigid instruments to simplify complex endoscopic procedures
ترجمه فارسی عنوان
تروکر جدید Intraastric Trorac رونمایی شده توسط روش PEG اجازه استفاده غدد لنفاوی از دستگاه های سخت برای ساده سازی روش های اندوسکوپی پیچیده را می دهد
کلمات کلیدی
ESD، دیسکسیون زیرمخاطی آندوسکوپی؛ FTR، تمام ضخامت برداشتن؛ GEJ، اتصال به دستگاه گوارش PEG، گاستروستومی آندوسکوپی پوستی؛ PIT، تروکار داخل معده از راه پوست
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیماری‌های گوارشی
چکیده انگلیسی

Background and AimsThe lack of triangulation has restricted the growth of flexible endoscopic surgical techniques. In addition, endoscope channel size limits the type of tools that can be used. A novel percutaneous intragastric trocar (PIT) has been developed to address these issues. The aim of this study was to evaluate the procedural characteristics of PIT placement and removal, as well as its therapeutic applications.MethodsWe placed 10 PIT devices in 8 Yorkshire pigs. We performed therapeutic procedures in 5 animals, including 3 endoscopic submucosal dissections (ESD), 2 gastroesophageal junction stapling procedures, and 2 full-thickness resections (FTR). Access site closure was standardized and performed in each animal, and leak testing was then completed. Immediately after this, necropsy was performed to determine whether acute adverse events had occurred. The primary endpoint was technical success, with secondary endpoints of successful access site closure and therapeutic procedure time.ResultsTen devices in 8 pigs were placed successfully (100%) into the stomach without adverse events. ESD was completed in 3 cases with a mean time of 13.5 minutes. Stapling at the gastroesophageal junction and FTR were each completed in 2 cases. Full-thickness suture closure was determined to be complete and successful on leak test in all 10 closure attempts. Necropsy revealed no acute adverse events in all cases.ConclusionsThe PIT device, deployed using the standard procedural steps of percutaneous endoscopic gastrostomy tube placement, is safe and effective for use in the porcine model. PIT allows use of rigid instruments not previously available to the flexible endoscopist, including laparoscopic staplers, and potentially shortens procedure times for complex endoscopic techniques by allowing adjustable tissue traction.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Gastrointestinal Endoscopy - Volume 84, Issue 3, September 2016, Pages 518–522
نویسندگان
, , ,