کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3304613 1210338 2012 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Diagnostic accuracy of conventional and cholangioscopy-guided sampling of indeterminate biliary lesions at the time of ERCP: a prospective, long-term follow-up study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیماری‌های گوارشی
پیش نمایش صفحه اول مقاله
Diagnostic accuracy of conventional and cholangioscopy-guided sampling of indeterminate biliary lesions at the time of ERCP: a prospective, long-term follow-up study
چکیده انگلیسی

BackgroundThe diagnostic accuracy of cholangioscopy-guided sampling has not been rigorously evaluated.ObjectiveTo prospectively evaluate the accuracy of cholangioscopy-guided mini-forceps sampling and compare it with standard cytology brushings and forceps biopsies for the tissue diagnosis of indeterminate biliary lesions.DesignProspective, long-term follow-up, paired design cohort study.SettingTertiary center.PatientsPatients undergoing cholangioscopy for the evaluation of indeterminate biliary lesions.InterventionsEach patient underwent triple sampling with cholangioscopy-guided mini-forceps, cytology brushing, and standard forceps.Main Outcome MeasurementsDiagnostic accuracy of each sampling method compared with the patient final status (cancer vs no cancer).ResultsA total of 26 patients (17 cancer positive/9 cancer negative) were enrolled. The mean follow-up in the patients with no cancer was 21.78 (SD ±6.78) months. The procedure was technically successful in all cases (100%). Sample quality was adequate in 25 of 26 (96.2%) of the cytology brushings, in 26 of 26 (100%) of the standard forceps biopsies, and in 25 of 26 (96.2%) of the mini-forceps biopsies. The sensitivity, accuracy, and negative predictive values were 5.9%, 38.5%, and 36% for standard cytology brushings; 29.4%, 53.8%, and 42.8% for standard forceps biopsies; and 76.5%, 84.6%, and 69.2% for mini-forceps biopsies, respectively. When comparing the 3 methods of sampling, mini-forceps biopsy provided significantly better sensitivity and overall accuracy compared with standard cytology brushing (P < .0001) and standard forceps biopsy (P = .0215).LimitationsPotential for selection bias.ConclusionsCholangioscopy-guided biopsies of indeterminate biliary lesions have significantly higher accuracy compared with ERCP-guided cytology brushings and standard forceps biopsies, but negative findings on mini-forceps biopsy cannot rule out malignancy with a high degree of certainty. (Clinical trial registration number: NCT01227382.)

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Gastrointestinal Endoscopy - Volume 75, Issue 2, February 2012, Pages 347–353
نویسندگان
, , , , , , ,