کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3306269 1210366 2009 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Newly designed stent for endoscopic bilateral stent-in-stent placement of metallic stents in patients with malignant hilar biliary strictures: multicenter prospective feasibility study (with videos)
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیماری‌های گوارشی
پیش نمایش صفحه اول مقاله
Newly designed stent for endoscopic bilateral stent-in-stent placement of metallic stents in patients with malignant hilar biliary strictures: multicenter prospective feasibility study (with videos)
چکیده انگلیسی

BackgroundEndoscopic management of malignant hilar biliary strictures is difficult even for an experienced endoscopist. Moreover, endoscopic placement of bilateral metal stents is considered very difficult and complicated.ObjectiveWe explored the feasibility and efficacy of the placement of a newly designed metal stent for an endoscopic bilateral stent-in-stent procedure for the management of malignant hilar biliary strictures.DesignMulticenter prospective feasibility study.SettingFive academic tertiary referral centers.PatientsThirty-five patients with malignant hilar biliary strictures of Bismuth type II or higher were enrolled.InterventionsBilateral stent placement by an endoscopic stent-in-stent procedure.Main Outcome MeasurementsTechnical success, functional success, early and late complications, stent patency.ResultsThe overall technical success rate of the newly designed metal stent was 94.3% (33/35). The success rate of the stent-in-stent procedure in a single session was 82% (27/33) per protocol and 77% (27/35) as intent to treat. In cases in which the initial stent-in-stent procedure failed, patients underwent the endoscopic stent-in-stent procedure for contralateral stent placement at 2 days (6%, 2/33) or 4 days (12%, 4/33) after the initial stent placement. There was no percutaneous insertion of a contralateral stent in these patients. There was no stent-related early or late complication in any enrolled patient. Functional success was 100% (33/33). Reintervention because of stent malfunction was 6% (2/33). These 2 patients showed sludge formation in the stent. During follow-up, there was no stent tumor ingrowth or overgrowth in the placed stent in any enrolled patient. According to the Kaplan-Meier analysis, median survival and stent patency were 180 days and 150 days, respectively.LimitationsAn uncontrolled feasibility study with a small patient population and a limited follow-up period.ConclusionThe newly designed metal stent for the endoscopic bilateral stent-in-stent procedure may be feasible and effective for malignant hilar biliary strictures.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Gastrointestinal Endoscopy - Volume 69, Issue 7, June 2009, Pages 1357–1360
نویسندگان
, , , , , , , , , , , ,