کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3306596 1210371 2010 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Endoscopic submucosal dissection of gastric lesions by using a Master and Slave Transluminal Endoscopic Robot (MASTER)
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیماری‌های گوارشی
پیش نمایش صفحه اول مقاله
Endoscopic submucosal dissection of gastric lesions by using a Master and Slave Transluminal Endoscopic Robot (MASTER)
چکیده انگلیسی

BackgroundPerforming endoscopic submucosal dissection (ESD) by using standard endoscopy platforms is technically challenging because of the equipment's lack of dexterity.ObjectiveTo explore the feasibility of using the Master and Slave Transluminal Endoscopic Robot (MASTER), a novel robotics-enhanced endosurgical system, to perform ESD.DesignESD was performed on simulated gastric lesions in 5 Erlangen porcine stomach models (ex vivo) and 5 live pigs (in vivo). Performance of ESD by using the MASTER was compared with that using the insulation-tipped (IT) diathermic knife.SettingSMART Laboratory, Advance Surgical Training Centre, National University Hospital, Singapore.SubjectsFive Erlangen porcine stomach models and 5 pigs, 5 to 7 months old, each weighing about 35 kg.InterventionsESD.Main Outcome MeasurementsLesion resection time, grasper and hook efficacy grade, completeness of resection, and presence of procedure-related perforation.ResultsIn the Erlangen stomach models, 15 simulated lesions from the cardia, antrum, and body were removed en bloc (mean dimension, 37.4 × 26.5 mm) by electrocautery excision using the MASTER. The mean ESD time was 23.9 minutes (range 7-48 minutes). There was no difference in the dissection times of lesions at different locations (P = .449). In the live pigs, the MASTER took a mean of 16.2 minutes (range 3-29 minutes) to complete the ESD of 5 gastric lesions, whereas the IT diathermic knife took 18.6 minutes (range 9-34 minutes). There was no significant difference in the times taken (P = .708). All lesions were excised en bloc; the mean dimensions of lesions resected by the MASTER and the IT diathermic knife were 37.2 × 30.1 mm and 32.78 × 25.6 mm, respectively. The MASTER exhibited good grasping and cutting efficiency throughout. Surgical maneuvers were achieved with ease and precision. There was no incidence of excessive bleeding or stomach wall perforation.LimitationsExploratory study with limited sample size.ConclusionsPerforming ESD by using the MASTER is feasible.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Gastrointestinal Endoscopy - Volume 72, Issue 3, September 2010, Pages 593–599
نویسندگان
, , , , , , , , , , ,