کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3306890 1210375 2008 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A multicenter randomized comparison of the Endocapsule and the Pillcam SB
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیماری‌های گوارشی
پیش نمایش صفحه اول مقاله
A multicenter randomized comparison of the Endocapsule and the Pillcam SB
چکیده انگلیسی

BackgroundVideo capsule endoscopy has been shown to be the single most effective endoscopic procedure for identifying the source of obscure GI bleeding (OGIB).ObjectiveOur purpose was to report on the Food and Drug Administration pivotal trial in which the Endocapsule (EC) (Olympus America, Allentown, Pa) was compared with the Pillcam SB (PSB) (Given Imaging, Yoqneam, Israel) in patients with OGIB.DesignA novel trial design was used in which the EC and the PSB were swallowed by the same patient 40 minutes apart, in randomized order.SettingFour academic medical centers.PatientsPatients with OGIB aged 18 to 85 years who had either been transfused or who had a hematocrit of <31% in males or <28% in females.InterventionsBoth video capsules were swallowed in random order. Videos from the PSB were read locally for patient management. All videos were then read by at least 2 independent readers for normal versus abnormal categorization, a diagnosis, capsule transit time, reading time, and a subjective assessment of image quality.Main Outcome MeasurementCategorization of videos as either normal or abnormal.ResultsData from 51 of 63 enrolled patients were analyzed. Nine patients were excluded for technical reasons and 3 for protocol violations. Twenty-four videos were read as normal and 14 as abnormal from both capsules. Disagreement occurred in 13. No adverse events were reported for either capsule. Overall agreement was 38 of 51 (74.5%) with a κ of 0.48, P = .008.LimitationsAlthough ingestion order was randomized, the videos could not be read blind owing to a different shape of the image margin.Conclusions(1) Both devices were safe and had a comparable diagnostic yield within the range previously reported. (2) There was a subjective difference in image quality favoring the EC. (3) This study design provided unique information about capsule movement in the small intestine and the lack of electromechanical interference between 2 different capsules.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Gastrointestinal Endoscopy - Volume 68, Issue 3, September 2008, Pages 487–494
نویسندگان
, , , , , , , , , , , ,