کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3449371 1595758 2009 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development and Evaluation of a New Measure for Muscle Tone of Ankle Plantar Flexors: the Ankle Plantar Flexors Tone Scale
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی و دندانپزشکی (عمومی)
پیش نمایش صفحه اول مقاله
Development and Evaluation of a New Measure for Muscle Tone of Ankle Plantar Flexors: the Ankle Plantar Flexors Tone Scale
چکیده انگلیسی

Takeuchi N, Kuwabara T, Usuda S. Development and evaluation of a new measure for muscle tone of ankle plantar flexors: the Ankle Plantar Flexors Tone Scale.ObjectiveTo develop and evaluate the reliability and concurrent validity of a clinically feasible measure for muscle tone of the ankle plantar flexors.DesignCross-sectional reliability and validity study of the Ankle Plantar Flexors Tone Scale.SettingDepartment of rehabilitation in a general hospital.ParticipantsPatients (N=74) with cerebrovascular disease.InterventionsNot applicable.Main Outcome MeasuresMuscle tone of the ankle plantar flexors was measured using the Ankle Plantar Flexors Tone Scale, the Modified Ashworth Scale (MAS), quality of muscle reaction with the Modified Tardieu Scale, and passive resistive joint torque with a handheld dynamometer. Intrarater and interrater reliabilities were assessed using the Cohen kappa coefficient (κ). Internal consistency was assessed using the Cronbach alpha (α). Concurrent validity was assessed with the Spearman rank correlation coefficient (ρ).ResultsThe Ankle Plantar Flexors Tone Scale included 3 items: stretch reflex, middle range resistance, and final range resistance. Intrarater and interrater reliabilities and internal consistency of the Ankle Plantar Flexors Tone Scale showed moderate to excellent agreement (κ=.63–.94; α=.81). Concurrent validity of the Ankle Plantar Flexors Tone Scale was low to very high among the 3 items of the Ankle Plantar Flexors Tone Scale and existing measures. The Spearman rank correlation coefficient showed high to very high correlation between stretch reflex and quality of muscle reaction as indices of the central component (ρ=.85–.94). Middle range resistance and final range resistance as indices of the peripheral component had low to moderate correlation with passive resistive joint torque using a handheld dynamometer and MAS (ρ=.44–.68).ConclusionsThe Ankle Plantar Flexors Tone Scale allows measurement of ankle plantar flexor tone in greater detail than existing subjective measures and provides a reliable and valid method for research and clinical use.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Archives of Physical Medicine and Rehabilitation - Volume 90, Issue 12, December 2009, Pages 2054–2061
نویسندگان
, , ,