کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3450477 1595743 2011 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Single Blind, Prospective, Randomized Controlled Trial Comparing Dorsal Aluminum and Custom Thermoplastic Splints to Stack Splint for Acute Mallet Finger
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی و دندانپزشکی (عمومی)
پیش نمایش صفحه اول مقاله
Single Blind, Prospective, Randomized Controlled Trial Comparing Dorsal Aluminum and Custom Thermoplastic Splints to Stack Splint for Acute Mallet Finger
چکیده انگلیسی

O'Brien LJ, Bailey MJ. Single blind prospective, randomized controlled trial comparing dorsal aluminum and custom thermoplastic splints to stack splint for acute mallet finger.ObjectiveTo compare Stack, dorsal, and custom splinting techniques in people with acute type 1a or b mallet finger.DesignMulti-center randomized controlled trial.SettingOutpatient hand therapy clinics (2 public hospitals and 1 private clinic).ParticipantsPatients (N=64) with acute type 1a or b mallet finger.InterventionsPrefabricated Stack splint (control), dorsal padded aluminum splint, or custom-made thermoplastic thimble splint. All were worn for 8 weeks continuously, with a 4 week graduated withdrawal and exercise program.Main Outcome MeasuresThe primary outcome was extensor lag at 12 and 20 weeks. Secondary outcomes were incidence of treatment failure, complications, range of motion of the distal interphalangeal joint, pain (visual analog scale) patient compliance, and patient satisfaction.ResultsThere was no difference in the primary outcome between groups at 12 or 20 weeks; however, the Stack and dorsal splints had significant rates of treatment failure (23.8% in both groups, compared to none in the thermoplastic group; P=.04). There was a medium negative correlation between patient compliance and degree of extensor lag. No significant differences between groups were observed for patient satisfaction or pain.ConclusionsAs splints for mallet finger must be worn continuously for 6 to 8 weeks, and compliance correlates with favorable outcomes, treating practitioners must ensure the splint provided is robust enough for daily living requirements and does not cause complications, which are intolerable to the patient. In this study, no extensor lag difference was found between the 3 splint types, but custom-made thermoplastic splints were significantly less likely to result in treatment failure.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Archives of Physical Medicine and Rehabilitation - Volume 92, Issue 2, February 2011, Pages 191–198
نویسندگان
, ,