کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3450527 1595748 2010 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Minimal Detectable Change in Quadriceps Strength and Voluntary Muscle Activation in Patients With Knee Osteoarthritis
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی و دندانپزشکی (عمومی)
پیش نمایش صفحه اول مقاله
Minimal Detectable Change in Quadriceps Strength and Voluntary Muscle Activation in Patients With Knee Osteoarthritis
چکیده انگلیسی

Kean CO, Birmingham TB, Garland SJ, Bryant DM, Giffin JR. Minimal detectable change in quadriceps strength and voluntary muscle activation in patients with knee osteoarthritis.ObjectiveTo examine the test-retest reliability and quantify the minimal detectable change (MDC) in quadriceps strength and voluntary activation in patients with knee osteoarthritis (OA).DesignRepeated measures over a 1-week interval.SettingTertiary care center.ParticipantsA convenience sample of patients (N=20) diagnosed with knee OA.InterventionIsokinetic and isometric quadriceps strength testing and voluntary quadriceps activation testing using interpolated twitch technique.Main Outcome MeasuresPeak isokinetic and isometric knee extension torque (Nm) and percentage of voluntary quadriceps activation (%).ResultsThe mean differences with 95% confidence intervals between the 2 test sessions for quadriceps isokinetic strength, isometric strength, and percent of voluntary activation were −4.34Nm (−14.01 to 5.34Nm), 1.56Nm (−5.56 to 8.68Nm), and 1.34% (−.53 to 3.22%), respectively. The intraclass correlation coefficients for all measures ranged from .93 to .98. The standard errors of measurement (SEMs) for quadriceps isokinetic and isometric strength were 14.57Nm and 10.76Nm, respectively. The SEM for percentage of voluntary activation was 2.84%. Based on these values, the MDCs were 33.90Nm, 25.02Nm, and 6.60% for quadriceps isokinetic strength, isometric strength, and percentage of voluntary activation, respectively.ConclusionsMaximal quadriceps isokinetic strength, isometric strength, and percentage of voluntary activation measures demonstrate excellent test-retest reliability in patients with knee OA. In addition to research applications, the present findings suggest these measures are appropriate for use when evaluating change in neuromuscular function of the quadriceps in individual patients.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Archives of Physical Medicine and Rehabilitation - Volume 91, Issue 9, September 2010, Pages 1447–1451
نویسندگان
, , , , ,